The following is a quick troubleshooting guide on the Reverse Osmosis. Please contact Le Fay’s service department to understand how to proceed should any inconvenience arise.
If you face any inconveniences please contact our service department immediately.
|
WHAT TO CHECK |
HOW TO CORRECT |
|
Tank Improperly Pressurized |
Set Tank Pressure at 5-7 psi When Empty |
|
Water Supply Turned Off |
Turn On |
|
Low Water Pressure (40 psi min.) |
Call Dealer For Assistance |
|
Pre-Filter Clogged |
Replace |
|
Module Damaged or Clogged |
Replace |
|
Product Line Crimped |
Remove Crimp |
|
Post-Filter Clogged |
Replace |
|
Ball Valve Closed on Storage Tank |
Move Valve to Up Position |
|
Check Valve/Restrictor Valve Clogged |
Replace |
|
WHAT TO CHECK |
HOW TO CORRECT |
|
Post-Filter Clogged |
Replace |
|
Low Air In Holding Tank |
Raise Pressure to 5-7 psi When Empty |
|
Pre-Filter Clogged |
Replace |
|
Low Water Pressure (40 psi min.) |
Call Dealer For Assistance |
|
Check Valve/Restrictor Valve Clogged |
Replace |
|
WHAT TO CHECK |
HOW TO CORRECT |
|
Threaded End Cap Leak |
Lube O-Ring and Tighten |
|
Compression Fitting Leak |
Tighten, Apply Teflon Tape, or Replace |
|
Leak At Screw Cap |
Replace O-Ring if Damaged |
|
WHAT TO CHECK |
HOW TO CORRECT |
|
Leak at Compression Fitting |
Tighten, Apply Teflon Tape, or Replace |
|
Leak at Post-Filter Seam |
Replace |
|
WHAT TO CHECK |
HOW TO CORRECT |
|
Fitting Leak |
Tighten or Replace |
|
Leak at Base or Brass Barbs |
Replace Faucet |
|
Faucet Drips |
Install Faucet Repair Kit |
|
Overflow at Air Gap |
Shorten 3/8" Line From Faucet to Drain Connection |
|
|
Clean 3/8" Line From Faucet to Drain Connection |
|
WHAT TO CHECK |
HOW TO CORRECT |
|
Defective Membrane |
Replace |
|
Restriction in Waste Flow |
Clear |
|
Carbon Post-Filter |
Replace |
|
Growth in Tank |
Sanitize |
|
Low Water Pressure (40 psi min) |
Call Dealer for Assistance |
|
Check Valve/Restrictor Valve Clogged |
Replace |